The high voltage lines providing power to the MFN via the CVT for CE09OSSM-00004 shorted out on 2017-01-22 at 08:31 UTC. Sea state was high, but not unusual for this time of year. Disabled future power scheduling to the MFN and applied an override to disable the CVT. No further data will be logged from the instruments on the MFN. This affects:
On DCL35:
* ADCPS (had already failed upon deployment)
* PCO2W -- should continue to autosample
* PHSEN -- should continue to autosample
* PRESF -- should continue to autosample
* VEL3D -- should continue to autosample
On DCL37
* CTDBP (plus DOSTA) -- should continue to autosample
* OPTAA
* ZPLSC -- had stopped reporting data early on in deployment, may still be autosampling