Data Concentrator Logger (DCL)

Reference Designator
CP03ISSM-MFD35-00-DCLENG000
Start Depth
91.5
End Depth
91.5
Location
Current Status
Engineering
Class
DCLEN (Data Concentrator Logger (DCL))
Series
DCLEN-G
Science Discipline
Make
WHOI
Model
Data Concentrator Logger
M2M Example
https://ooinet.oceanobservatories.org/api/m2m/12576/sensor/inv/CP03ISSM/MFD35/00-DCLENG000/metadata
Method Data Stream Content Type
recovered_host cg_dcl_eng_dcl_cpu_uptime_recovered CPU Uptime Data Report M2M Engineering
recovered_host cg_dcl_eng_dcl_dlog_aarm_recovered Accelerometer Data Report M2M Engineering
recovered_host cg_dcl_eng_dcl_dlog_mgr_recovered Data Log Manager Report M2M Engineering
recovered_host cg_dcl_eng_dcl_dlog_status_recovered Data Logger Status Report M2M Engineering
recovered_host cg_dcl_eng_dcl_error_recovered Error Data Report M2M Engineering
recovered_host cg_dcl_eng_dcl_gps_recovered GPS Data Report M2M Engineering
recovered_host cg_dcl_eng_dcl_msg_counts_recovered Message Counts Data Report M2M Engineering
recovered_host cg_dcl_eng_dcl_pps_recovered Pulse Data Report M2M Engineering
recovered_host cg_dcl_eng_dcl_status_recovered Status Data Report M2M Engineering
recovered_host cg_dcl_eng_dcl_superv_recovered Leak Detect Data Report M2M Engineering
telemetered cg_dcl_eng_dcl_cpu_uptime CPU Uptime Data Report M2M Engineering
telemetered cg_dcl_eng_dcl_dlog_aarm Accelerometer Data Report M2M Engineering
telemetered cg_dcl_eng_dcl_dlog_mgr Data Log Manager Report M2M Engineering
telemetered cg_dcl_eng_dcl_dlog_status Data Logger Status Report M2M Engineering
telemetered cg_dcl_eng_dcl_error Error Data Report M2M Engineering
telemetered cg_dcl_eng_dcl_gps GPS Data Report M2M Engineering
telemetered cg_dcl_eng_dcl_msg_counts Message Counts Data Report M2M Engineering
telemetered cg_dcl_eng_dcl_pps Pulse Data Report M2M Engineering
telemetered cg_dcl_eng_dcl_status Status Data Report M2M Engineering
telemetered cg_dcl_eng_dcl_superv Leak Detect Data Report M2M Engineering
Deployment Cruise Start Date Stop Date Mooring Asset Node Asset Sensor Asset Latitude Longitude Deployment Depth Water Depth
1 Review KN-224 12/14/2014 12/30/2014 CGMCP-03ISSM-00001 CGCON-MDCL35-00008 40.3622 -70.8786 94 94
2 Review AT-27 05/09/2015 10/21/2015 CGMCP-03ISSM-00002 CGCON-MDCL35-00012 40.3595 -70.8853 97 97
3 Review AT-31 10/21/2015 05/14/2016 CGMCP-03ISSM-00003 CGCON-MDCL35-00016 40.3647 -70.8884 96 96
4 Review AR-04 05/28/2016 10/15/2016 CGMCP-03ISSM-00004 CGCON-MDCL35-00013 40.3595 -70.885 95 95
5 Review AR-08B 10/11/2016 06/15/2017 CGMCP-03ISSM-00005 CGCON-MDCL35-00008 40.3619 -70.8783 92 92
6 Review AR-18 06/15/2017 11/01/2017 CGMCP-03ISSM-00006 CGCON-MDCL35-00007 40.3671 -70.8816 93 93
7 Review AR-24 11/01/2017 03/28/2018 CGMCP-03ISSM-00007 CGCON-MDCL35-00041 40.359 -70.8855 93 93
8 Review AR-28 03/25/2018 10/26/2018 CGMCP-03ISSM-00008 CGCON-MDCL35-00045 40.3672 -70.8821 94 94
9 Review AR-31 10/29/2018 CGMCP-03ISSM-00009 CGCON-MDCL35-00041 40.3673 -70.8811 92 92

No notes yet.

New Note

Metadata Start Date End Date Comment
CP03ISSM-MFD35
12/14/14, 1:52 PM 12/29/14, 7:00 PM

Telemetered and recovered host data are unavailabe because of ground faults on the sealoor Multi-Function Node. All communications to the instruments were shut down.

Id: 315 By: leila

CP03ISSM-MFD35-00-DCLENG000
5/8/15, 8:57 PM 10/21/15, 2:50 PM

Engineering recovered host data were not routinely captured.

Id: 444 By: leila

CP03ISSM-MFD35
2/3/17, 1:05 AM 3/29/17, 10:00 PM

All seafloor Multi-Function Node (MFD35 and MFD37) instruments have ceased data telemetry because the seafloor multi-function node had a high voltage ground fault and has been shut down to protect the instruments. Instrument on battery power will continue to collect data.

Id: 332 By: leila

CP03ISSM-MFD35
12/20/17, 4:00 AM 3/28/18, 12:56 PM

Deployment 7: Multi-Function Node failed.

Id: 334 By: leila
Flag: not_operational Exclude: No

CP03ISSM-MFD35
Method: telemetered
6/12/18, 7:05 AM 10/28/18, 11:43 PM

Data telemetry disabled due to chronic issues with power generation and management. The instruments could be revived to send data via telemetry when sufficient power is available. Note: Instruments may continue to collect data on internal battery power.

Id: 1512 By: leila