Asset: CGINS-FLORTD-01214

Type
Sensor
Mobile
0
Description of Equipment
3-Wavelength Fluorometer: FLORT Series D
Manufacturer
WET Labs
Model
ECO Triplet-w
Manufacturer Serial No
1214
Firmware Version
Acquisition Date
6/27/14
Original Cost
$13,013.52
Comments
Deployment Cruise Reference Designator Deployment Number Start Date Stop Date Mooring Asset Node Asset Sensor Asset Latitude Longitude Deployment Depth Water Depth
AT-26-30 GA01SUMO-RID16-02-FLORTD000 1 03/15/2015 11/26/2015 CGMGA-01SUMO-00001 CGINS-FLORTD-01214 -42.9228 -42.4558 12 5181
NBP16-10 GS03FLMB-RIS01-05-FLORTD000 3 12/03/2016 12/03/2017 CGMGS-03FLMB-00003 CGINS-FLORTD-01214 -54.0803 -88.9318 30 4928

No notes yet.

Class Asset UID Start Date Serial Name Value Notes
FLORTD CGINS-FLORTD-01214 03/15/2015 1214 CC_angular_resolution 1.076 Constant
FLORTD CGINS-FLORTD-01214 03/15/2015 1214 CC_dark_counts_cdom 43
FLORTD CGINS-FLORTD-01214 03/15/2015 1214 CC_dark_counts_chlorophyll_a 52
FLORTD CGINS-FLORTD-01214 03/15/2015 1214 CC_dark_counts_volume_scatter 51
FLORTD CGINS-FLORTD-01214 03/15/2015 1214 CC_depolarization_ratio 0.039 Constant
FLORTD CGINS-FLORTD-01214 03/15/2015 1214 CC_measurement_wavelength 700 Constant
FLORTD CGINS-FLORTD-01214 03/15/2015 1214 CC_scale_factor_cdom 0.0908
FLORTD CGINS-FLORTD-01214 03/15/2015 1214 CC_scale_factor_chlorophyll_a 0.0121
FLORTD CGINS-FLORTD-01214 03/15/2015 1214 CC_scale_factor_volume_scatter 1.851e-06
FLORTD CGINS-FLORTD-01214 03/15/2015 1214 CC_scattering_angle 124 Constant
FLORTD CGINS-FLORTD-01214 12/03/2016 1214 CC_angular_resolution 1.076 Constant
FLORTD CGINS-FLORTD-01214 12/03/2016 1214 CC_dark_counts_cdom 45
FLORTD CGINS-FLORTD-01214 12/03/2016 1214 CC_dark_counts_chlorophyll_a 53
FLORTD CGINS-FLORTD-01214 12/03/2016 1214 CC_dark_counts_volume_scatter 51 Requires TEMPWAT and PRACSAL (PD2927/2929) from a nearby CTD
FLORTD CGINS-FLORTD-01214 12/03/2016 1214 CC_depolarization_ratio 0.039 Constant
FLORTD CGINS-FLORTD-01214 12/03/2016 1214 CC_measurement_wavelength 700 Constant
FLORTD CGINS-FLORTD-01214 12/03/2016 1214 CC_scale_factor_cdom 0.0924
FLORTD CGINS-FLORTD-01214 12/03/2016 1214 CC_scale_factor_chlorophyll_a 0.0122
FLORTD CGINS-FLORTD-01214 12/03/2016 1214 CC_scale_factor_volume_scatter 2.109e-06 Depth
FLORTD CGINS-FLORTD-01214 12/03/2016 1214 CC_scattering_angle 124 Constant
FLORTD CGINS-FLORTD-01214 08/01/2018 1214 CC_angular_resolution 1.076 Constant
FLORTD CGINS-FLORTD-01214 08/01/2018 1214 CC_dark_counts_cdom 44
FLORTD CGINS-FLORTD-01214 08/01/2018 1214 CC_dark_counts_chlorophyll_a 52
FLORTD CGINS-FLORTD-01214 08/01/2018 1214 CC_dark_counts_volume_scatter 50
FLORTD CGINS-FLORTD-01214 08/01/2018 1214 CC_depolarization_ratio 0.039 Constant
FLORTD CGINS-FLORTD-01214 08/01/2018 1214 CC_measurement_wavelength 700 Constant
FLORTD CGINS-FLORTD-01214 08/01/2018 1214 CC_scale_factor_cdom 0.0843
FLORTD CGINS-FLORTD-01214 08/01/2018 1214 CC_scale_factor_chlorophyll_a 0.0122
FLORTD CGINS-FLORTD-01214 08/01/2018 1214 CC_scale_factor_volume_scatter 2.268e-06
FLORTD CGINS-FLORTD-01214 08/01/2018 1214 CC_scattering_angle 124 Constant